◆ High-performance 32-bit ARM microprocessor is used to carry out signal processing and intelligent control in real time;
◆ LCD Chinese/English display provides friendly HMI and simple operation;
◆ Long delay, short delay and instantaneous three-stage protection, electronic tripping mode is applied, which is independent of supply voltage;
◆ High breaking ability could ensure the reliability of short circuit protection for the line;
◆ In current fault protection, the fault reasons can be stored and reported;
◆ Detailed real-time information of load can be queried: current, voltage and phase loss;
◆ It integrates comprehensive electrical protection of short circuit, overload, overvoltage and undervoltage, and phase loss;
◆ Built-in communication function: Remote communication, telemetry, remote control and remote adjustment could be achieved.
Operating and Installation Conditions
◆ Ambient temperature: -5℃~+40℃, and the average value does not exceed + 35℃ within 24 hours;
◆ Altitude: ≤ 2000m;
◆Relative humidity of air: ≤ 95%;
◆ Installation category:3;
◆ Pollution level: 3;
◆ Installation mode: Horizontal or vertical;
◆ Installation conditions: The external magnetic field shall not exceed 5 times of the geomagnetic
field in any direction.
Model | CBRM1E-125 | CBRM1E-250 | CBRM1E-400 | CBRM1E-630 | CBRM1E-800 | CBRM1E-1250 | |||||||
Shell current Inm(A) | 125 | 250 | 400 | 630 | 800 | 1250 | |||||||
Rated current In | 32 | 63 | 125 | 250 | 400 | 630 | 800 | 1250 | |||||
Setting current Ir1 (A) at overload long delay |
16,20, 25,32 | 32,35, 40,45, 50,55, 60,63 | 63,65, 70,75, 80,85, 90,95, 100,125 | 100,125, 140,160, 180,200, 225,250 | 160,180, 200,225, 250,280, 315,350, 375,400 | 250,280, 315,350, 375,400, 450,500, 560,630 | 315,350, 400,450, 500,560, 630,700, 750,800 | 400,500, 630,700, 800,900, 1000,1100, 1250 | |||||
Rated Ue(V) | working voltage | 400 | 400 | ||||||||||
Rated insulation voltage Ui(V) | 1000 | 1000 | |||||||||||
Rated impulse withstand voltage Uimp(V) | 8000 | 8000 | |||||||||||
No. of poles | 3,4 | 3,4 | 3,4 | 3,4 | 3,4 | 3 | |||||||
Breaking ability level | L | M | L | M | L | M | L | M | L | M | |||
Rated limit short circuit breaking capacity Icu(kA) | AC400V | 36 | 50 | 36 | 50 | 50 | 70 | 50 | 70 | 50 | 70 | 80 | |
AC690V | __ | 20 | __ | 20 | __ | 20 | __ | 20 | __ | 20 | |||
Rated short circuit breaking capacity Ics(kA) | AC400V | 25 | 36 | 25 | 36 | 50 | 70 | 50 | 70 | 50 | 70 | 50 | |
AC690V | __ | 10 | __ | 10 | __ | 15 | __ | 15 | __ | 15 | |||
Rated short-time withstand current lcw(kAy1s | 5 | 5 | 8 | 10 | 15 | ||||||||
Utilization category | A | B | B | B | B | B | |||||||
Flashing distance (mm) | ≯50 | ≯50 | ≯100 | ≯100 | |||||||||
Servicea bility (times) | Powered | 1500 | 1000 | 1000 | 1000 | 1000 | 500 | ||||||
Not powered | 8500 | 7000 | 4000 | 4000 | 4000 | 2500 | |||||||
Total | 10000 | 8000 | 5000 | 5000 | 5000 | 3000 | |||||||
Overall dimension (mm) | W | 92 | 122 | 107 | 142 | 150 | 198 | 210 | 280 | 210 | 280 | 210 | |
L | 150 | 165 | 257 | 280 | 280 | 340 | |||||||
H | 92 | 90 | 106.5 | 115.5 | 115.5 | 138.5 |